AMT Dewpoint Transmitter for General Applications

  • Ultra-high capacitance aluminium oxide sensor delivers unsurpassed sensitivity, speed of response, accuracy, repeatability, stability, and long service life
  • Unique AutoCal span correction feature
  • Various dewpoint ranges available from -110 °C to 20 °C
  • Compact 2-Wire 4-20 mA Loop Powered Dewpoint Transmitter
  • Accuracy ±2 °C dewpoint
  • IP66 / NEMA 4 Weatherproof Protection
  • Optional Sensor Holder/Sample Cell for optimum sampling conditions
  • Supplied with a calibration certificate traceable to National and International Humidity standards

Model AMT Dewpoint Transmitter is a 2-wire 4-20 mA loop-powered transmitter that continuously measures moisture in process gas or compressed air. The 4-20 mA linear output signal can be factory configured for any of the following moisture units:- °C or °F dewpoint, ppm(V), ppb(V), g/m3, and lb/MMSCF.

At the heart of the AMT Dewpoint Transmitter is our ultra-high capacitance aluminium oxide sensor, which delivers unsurpassed sensitivity, speed of response, accuracy, repeatability, stability, and long service life. Every unit is supplied with a Calibration Certificate traceable to International Humidity Standards, guaranteeing accuracy to ± 2 ºC dew point.

Read More

Transmitter Type 2-Wire 4-20 mA Loop Powered Dewpoint Transmitter
Sensing Element Ultra-High Capacitance – Aluminium Oxide Type
Output Signal Linear 4-20 mA with selectable engineering units and fault indication
Power Supply 12-28 Vdc Reverse Polarity Protected
Dewpoint Ranges See datasheet
Electromagnetic Compatibility (EMC) Complies with BS EN ICE 61326-1
Accuracy ± 2 °C dewpoint (UK National Physical Laboratory traceable for range -90 °C to 20 °C)
Repeatability Better than ±0.3 °C dewpoint
Operating Temperature (Ambient and Process) -20 °C to 60 °C
Operating Pressure (Process) From 1 kPa (0.01 bara) to Maximum 35,000 kPa (350 bara)
Operating Humidity (Ambient) Maximum 95 %RH Non-Condensing
Storage Temperature -20 °C to 70 °C
Field Calibration AutoCal span check and correction are performed using two buttons on the Transmitter body. Locked in normal operating mode to avoid tamper. We recommend AutoCal is repeated every 2-3 months.
Factory Calibration Supplied with a calibration certificate traceable to National and International Humidity standards. We recommend annual laboratory calibration
Sample Flow Rate Flow independent, ideally 5 to 15 L/min, maximum 20 L/min
Cable Terminations IP66 / NEMA 4X rated, size C, DIN EN 175301 connector at the Transmitter and other end terminated with bootlace ferrules
Cable Supplied with 2 m standard cable. Nominal diameter 3.4 mm, 92 ohms/km at 20 °C
Mechanical Connection 3/4” UNF (16tpi) with integral Viton “O” ring seal
Isolation Sensing Element connected to the 4-20 mA loop but isolated from Transmitter body
Transmitter Body 316 Stainless Steel
Sensor Protection 316 Sintered Stainless Steel Filter – 50 micron
Probe Material (Wetted Parts) 316 Stainless Steel
Ingress Protection IP66 / NEMA 4X when Connector coupled to Transmitter
Manufacturer’s Warranty 24 months in case of defective parts or faulty workmanship
  • Calibration Certificate traceable to National and International Humidity standards
  • 2 m Connecting Cable

Related Products