Alpha Moisture Systems
 

 


SSI | SSII | SSIII | SSIV | Combined Systems | Natural Gas

Model SSI - Low Pressure Sample System

  • Sample inlet pressure up to 28 barg
  • Sensor operating at atmospheric pressure
  • Process and auxiliary sample inlets with manual selection valve
  • Outlet connection for sample recovery or disposal
  • Particulate filtration, 99.99% to 0.6 microns
  • Sample pressure control and indication
  • Sample flow control and indication, 0-5 l/min
  • Sample flow schematic and component labelling on front panel
  • Panel or surface mounting with optional weatherproof enclosure
  • Can be situated in a hazardous environment
Low Pressure Sample System - Maximum inlet pressure up to 28 barg, with sensor operating at atmospheric pressure.

This system is designed for gas or general compressed air sampling for maximum inlet pressure of 28 barg, with the moisture sensor operating at atmospheric pressure. The system provides for all necessary pressure and flow control and includes sample filtration to protect against particulate contamination. Auxiliary inlet connection is provided for a second sample stream or for injection of a calibration gas. An outlet connection is also included to allow sample recovery or disposal.

(For full details please request specification sheet Model SSI)

Back To The Top


Model SSII - Low Pressure Sample System

  • Exactly as Model SSI but with the sensor operating at inlet line pressure - Maximum 28 barg.
Low pressure sample system with sensor operating at maximum inlet pressure up to 28 barg.

(For full details please request specification sheet Model SSII)

Back To The Top


Model SSIII - High Pressure Sample System

  • Exactly as Model SSI but with two stage pressure regulation for maximum inlet pressure up to 340 barg.
  • Sensor operating at atmospheric pressure.
High pressure Sample System - Maximum inlet pressure up to 340 barg with sensor operating at atmospheric pressure.

(For full details please request specification sheet Model SSIII)

Back To The Top


Model SSIV - High Pressure Sample System

  • Exactly as Model SSI but with two stage pressure regulation for maximum inlet pressure up to 340 barg.
  • Sensor operating at inlet line pressure - Maximum 340 barg.
High pressure Sample System with sensor operating at maximum inlet pressure up to 340 barg.

(For full details please request specification sheet Model SSIV)

Back To The Top


Model Combined - Combined Sample System

  • Example shown is a Combined Sample System incorporating Model 200D on-line analyser with Model SSIII Sampling System.
All sample systems may be combined with any of the on-line analysers shown in pages 7-8 to form a complete turnkey solution. The resulting system can be supplied for panel or surface mounting with an optional weatherproof enclosure. Please contact us for further information.

(Please contact us for further information.)

Back To The Top


Natural Gas Sampling Systems

  • CENELEC certified sensor for use in hazardous areas*
  • Tough moisture sensor technology that is responsive to water vapour only
  • Constructed using high quality components to the highest standards of workmanship
  • All systems have IP66 rated Stainless Steel weatherproof enclosures as standard
  • All metal wetted parts are 316 Stainless Steel (NACE Compatible)
  • Filtration, pressure control and sample conditioning selected to suit specific application
  • High inlet pressures up to 240 barg
  • Sample and by-pass loop flows returned to process or disposed of through High Pressure or Low Pressure flare systems
Alpha Moisture Systems have considerable experience of moisture analysis in Natural Gas applications both on and off shore. A number of standard sample systems are available for common applications and our design engineers are able to provide custom made solutions to the more complex applications. Through close co-operation with customers during design, assembly and commissioning you can be assured that our Natural Gas sample systems will meet the most demanding standards for performance and reliability.

Common factors in many Natural Gas applications are extreme environmental conditions, high levels of contamination and high process pressures often with the process stream in liquid phase. In view of this, our Natural Gas systems have the following general features:

 
MODEL SSNGH

Basic Natural Gas Sampling System

  • Inlet Pressure up to 240 barg
  • Sensor Operates at Inlet or Atmospheric Pressure
  • Process and Auxiliary Inlet with Manual Selector Valves
  • Sample Inlet and Outlet Pressure Indication
  • Sample Flow Control and Indication
  • Electrically Heated Pressure Regulator for Control of Sample
  • Sample Outlet Fitted with Check Valve
  • System CENELEC Certified for use in Hazardous Area*
(For full details please request specification sheet Model SSNGH)

Model SSNGH Sample System is suitable for clean, sweet Natural Gas and is just one of a range of sample systems for Natural Gas application. Other systems offering Fast Loop Bypass, High Pressure sample return and the ability to cope with dirty or condensate laden samples are also available. These systems are tailored to specific requirements. (Please contact us for further details)

 
Hazardous Environment - Installation

* The sample system with moisture sensor can be housed in hazardous area with the analyser and zener barrier in a safe area.

Back To The Top